Automatic Ventilator Respirator for Patient with Variable BPM & Oximeter

  • Rahul G. Maprai
  • Chanakya Kumar Jha
Keywords: Cost effective, automated, ambu bag, mechanical, ventilator, covid-19, BPL, BPM, sensor.

Abstract

The article describes the development of a cost effective, automated portable respirator that delivers breaths using a conventional ambu bag that eliminates the need of a human operator. It’s a portable mechanical ventilator that delivers breathing using a standard ambu bag. The paper shows that this design can be utilized for mass casualty cases such as covid-19 in recent scenario and other poor resource environments. This system firstly measures the oxygen levels of the patient and accordingly the user can set a particular value through breath per length and breath per minute nodes, these values are pre-set for a certain amount of oxygen levels and should be accordingly set while using hence to take the maximum benefit of the model. In addition, the system includes a pressure sensor to measure the overall pressure within the system so as to provide more vital information regarding a patient’s health. After all, values are set as per standard requirements for machine according to which the motor within the system gets activated through microcontroller making ambu bag press, and providing the necessary air to the patient.

References

[1] McCluskey A, Gwinnett CL. Evaluation of the PneupacVentipac portable ventilator: comparison of performance in a mechanical lung and anaesthetized patients. Br J Anaesth 1995; 75: 645 –50.
[2] Dra¨ger Medical. Oxylog 3000 Emergency and Transport Ventilator—Instructions for Use. 2nd Edn. Hemel Hempstead: Dra¨ger Medical UK, 2002
[3] Austin PN, Campbell RS, Johannigman JA, Branson RD. Work of breathing characteristics of seven portable ventilators. Resuscitation 2001; 49:159–67.
[4] Emergency Care Research Institute. Portable/Transport Ventilators. Health Devices 2004; 33: 381–401.
[5] Lowes T, Sharley P. Oxygen Conservation during long-distance transport of ventilated patients. Air Med J 2005; 24: 164–71.
[6] Martin T. Aeromedical Transportation—A Clinical Guide. Aldershot, Hampshire: Ashgate Publishing Limited, 2006.
[7] Sonawane, Anagha, M. U. Inamdar, and Kishor B. Bhangale. "Sound based human emotion recognition using MFCC & multiple SVM." In 2017 international conference on information, communication, instrumentation and control (ICICIC), pp. 1-4. IEEE, 2017.
[8] Jabshetti, Gayatri C., M. S. Biradar, and Kishor Bhangale. "Object detection using Regionlet transform." In 2016 International Conference on Computing, Analytics and Security Trends (CAST), pp. 600-604. IEEE, 2016.
[9] Bhangale, Kishor B., Prashant Titare, Raosaheb Pawar, and Sagar Bhavsar. "Synthetic speech spoofing detection using MFCC and radial basis function SVM." IOSR J. Eng.(IOSRJEN) 8, no. 6 (2018): 55-62.
[10] Bhangale, Kishor B., and R. U. Shekokar. "Human body detection in static images using hog & piecewise linear svm." Int. J. Innov. Res. Dev 3, no. 6 (2014).
[11] L. N. Patil, R. G. Mapari and S. H. Bodake, "Solicitation of Wavelet Transforms for Satellite Picture Resolution Enrichment," 2015 Second International Conference on Advances in Computing and Communication Engineering, 2015, pp. 161-163, doi: 10.1109/ICACCE.2015.128.
Published
2018-08-13
How to Cite
Maprai, R. G., & Jha, C. K. (2018). Automatic Ventilator Respirator for Patient with Variable BPM & Oximeter. Asian Journal For Convergence In Technology (AJCT) ISSN -2350-1146, 4(II). Retrieved from http://www.asianssr.org/index.php/ajct/article/view/1216